Honeywell FSL100-UVIR
Honeywell FSL100-IR3
Honeywell FSL100-UVIR霍尼韦尔紫外红外火焰检测器 原装正品现货
FSL100-IR3是三重红外火焰检测器
FSL100-UVIR是UV/IR 紫外红外火焰检测器
FSL100-UVIR
UV/lR flame detector. Suitable for ATEX zone 2/22: FM 3611 Class 1.2&3 Div2
EN54-10(HIGH sensitivity)certificate FM3260 approval. Red Housing.

FSL100-IR3
Triple lR flame detector. Suitable for ATEX zone 2/22; FM 3611 Class 1,2&3 Div2
EN54-10(HIGH sensitivity)certificateFM3260 approval. Red Housing.
Triple

FSL100 Flame Detectors
FSL100 Series Flame Detectors UV, UVIR, IR3
Honeywell霍尼韦尔FSL100火焰探测器 FSL100-UV FSL100-UVIR FSL100-IR3
FSL100-SM21支架

FSL100系列火焰探测器来自
霍尼韦尔在广泛的应用中提供强大、快速和可靠的火焰检测。
该范围包括UV, UVIR和IR3火焰探测器。所有这些都利用了复杂的传感技术
和信号分析,以迅速发现火灾同时也拒绝假警报。
FSL100可能小而轻,为了便于安装,但它们是专门设计的
在艰苦的环境中工作而且有潜在的爆炸性atm。
有了广阔的视野,它们就能探测到一系列不同类型的火灾,包括烃源和非烃源。有UV, UVIR和3IR,我们有您的应用程序覆盖。

适用于多种应用
•UV, UVIR和IR3可用
•烃源和非烃源
•在潜在爆炸性环境中使用
•室内外操作
•高能见度红色或离散白色型号可用
伟大的成就
•通过EN54-10和FM3260火焰认证
探测器的标准
•全面的自动自检
•远程手动自检选项
快速可靠
•高速传感器和微处理器
•复杂的分析算法
•持续运行状况监控
•误报排除
降低生命成本
•长寿命元件
•压力补偿,避免污染
•2年保修
•自信地购买
易于安装和使用
•继电器和mA输出作为标准
•轻质玻璃钢外壳
•预成型淘汰赛
•可选旋转安装支架
•可提供远程测试灯

规格:FSL100系列火焰探测器
FSL100火焰探测器FSL100- uv, FSL100- uvir和FSL100- ir3;可选择红色或白色的外壳
范围35米/110英尺(IR3), 25米/80英尺(UV, UVIR)报警在10秒内0.1平方米(1平方英尺)正庚烷火灾
视锥最小90˚水平和垂直
电源12/24 VDC(标称10 - 28v DC)
●绿色常亮,表示工作正常
●黄色常亮:故障
●黄色闪烁:故障,自检失败后引导重复自检
●连续红色:报警
标准输出电流4 - 20ma(阶梯,下沉,非隔离)
•0 mA电源故障/微处理器故障
•2ma光故障
•4ma正常工作
•> 20ma告警
继电器输出:
-报警继电器正常运行时断电,无报警,SPDT, 30vdc - 2a,最大60w。
-故障继电器正常工作时通电,无故障,SPDT, 30vdc - 2a,最大60w。
电缆接头和端子电缆入口M20间隙。提供适用于电缆直径从5.5mm(0.2“)到13mm(0.5”)的压盖。端子适用于0.5mm2 (20AWG) ~ 1.5mm2 (15AWG)线
启动时间<10秒
报警响应时间8 ~ 30秒
报警输出设置可选择led和继电器闭锁/非闭锁;出厂设置:闭锁
自动、手动自检自动传感器测试(内置自检)和手动自检
工作电流正常25毫安在24 VDC
报警电流,24vdc±75ma 24vdc
连接:使用线端(EOL)和报警电阻(电流增加)的火控面板
通过继电器开关输出操作的设备
plc与4-20 mA输入
线端及报警电阻需调整至消防控制板;空闲端子专用于电阻
注意:报警电阻器和EOL电阻器的最小额定功率为2w,报警电阻器和EOL电阻器的总功耗不超过2w
外壳玻璃增强聚酯(GRP),不燃烧。抗紫外线,自熄V-0 (UL-94)
旋转安装PA66,抗紫外线;不锈钢固定件;280克(0.62磅)
压力补偿PCE(压力补偿元件)避免由于环境空气压力的变化而导致探测器外壳中的水分积聚
元素
尺寸125 x 80 x 57毫米(4.9 x 3.15 x 2.25英寸)
重量465克(1.05磅)
防护等级IP65
温度,工作温度-40˚C至+70˚C(-40˚F至+158˚F)
温度,环境温度-25˚C至+70˚C(-13˚F至+158˚F)

The FSL100 Series of flame detectors from
Honeywell delivers robust, fast and reliable detection of flaming fires in a wide range of applications.
The range consists of UV, UVIR and IR3 flame
detectors. All utilise sophisticated sensing
and signal analysis to detect fires quickly
while also rejecting false alarms.
The FSL100 may be small and lightweight
for easy installation but they are designed
to work in tough environments both in and
out of doors as well as potentially explosive
atmospheres.
With a large field of view they can detect
a range of different types of fire including
hydrocarbon and non hydrocarbon sources.
Available in UV, UVIR and 3IR we have your
application covered.

Suitable for Many Applications
• UV, UVIR and IR3 available
• Hydrocarbon and non hydrocarbon sources
• Use in potentially explosive atmospheres
• Indoor and outdoor operation
• High visibility red or discrete white models available
Great Performance
• Approved to EN54-10 and FM3260 flame
detector standards
• Comprehensive automatic self test
• Remote manual self test option
Fast & Reliable
• High speed sensors and microprocessor
• Sophisticated analysis algorithms
• Continuous health monitoring
• False alarm rejection
Reduced Life Cost
• Long life elements
• Pressure compensation to avoid contamination
• 2 year warranty
• Buy with confidence
Ease of Installation and Use
• Relay and mA outputs as standard
• Lightweight GRP housing
• Pre-formed knockouts
• Optional swivel mounting bracket
• Long range test lamp available

Specifications: FSL100 Series Flame Detectors
FSL100 Flame Detector types FSL100-UV, FSL100-UVIR and FSL100-IR3; Choice of red or white housings
Range 35 m/110 ft (IR3), 25 m/80 ft (UV, UVIR) alarming within 10 seconds to a 0.1 m2 (1 ft2) n-heptane fire
Cone of vision 90˚minimum horizontal and vertical
Power 12/24 VDC (10–28 V DC nominal)
Local LEDs ● Continuous green: normal operation
● Continuous yellow: fault
● Flashing yellow: Fault and guide to repeat self-test after a self-test failure
● Continuous red: alarm
Current output Standard available 4–20 mA (stepped, sinking, non-isolated)
• 0 mA power fault / microprocessor fault
• 2 mA optical fault
• 4 mA normal operation
• >20 mA alarm
Relay outputs:
- Alarm relay De-energised during normal operation, no alarm, SPDT, 30 VDC – 2 A, 60 W max.
- Fault relay Energised during normal operation, no fault, SPDT, 30 VDC – 2 A, 60 W max.
Cable gland & terminals Cable entry M20 clearance. Supplied with gland suitable for cable diameter from 5.5mm (0.2”) to 13mm (0.5”). Terminals suitable for 0.5mm2 (20AWG) to 1.5mm2 (15AWG) wire
Start up time <10 sec
Alarm response time 8 to 30 sec
Alarm output settings Selectable LEDs and relays latching/non latching; factory setting: latching
Automatic & manual Self-Test Automatic Sensor Test (Built in Self-Test) and manual self-test
Operating current normal 25 mA at 24 VDC
Current in alarm, at 24 VDC ±75 mA at 24 VDC
Connections to: fire control panels using end of line (EOL) and alarm resistors (current increase)
devices that operate via relay switched outputs
PLCs with 4–20 mA inputs
End of line and alarm resistor To be adjusted to the fire control panel; free terminals are dedicated to the resistors
Note: the alarm- and EOL resistor must be rated 2 W min. each and the total power dissipation of both alarm and EOL resistor should not exceed 2 W
Housing Glass Reinforced Polyester (GRP), Nonincendive. UV resistant, Self-Extinguishing V–0 (UL-94)
Swivel Mount PA66, UV resistant; Stainless Steel fixings; 280 g (0.62 lb)
Pressure compensating PCE (Pressure Compensating Element) avoids moisture build-up in the detector housing due to changes in ambient air-pressure
element
Dimensions 125 x 80 x 57 mm (4.9 x 3.15 x 2.25 in)
Weight 465 g (1.05 lb)
Ingress protection IP65
Temperature, operating –40 ˚C to +70 ˚C (–40 ˚F to +158 ˚F)
Temperature, ambient –25 ˚C to +70 ˚C (–13 ˚F to +158 ˚F)

Ordering Information
FSL100-UV (red housing) UV flame detector
FSL100-UV-W (white housing) Suitable for ATEX zone 2/22; FM 3611 Class 1, 2 & 3 Div 2
EN54-10 (HIGH sensitivity) certificate
FM3260 approval (pending*)
FSL100-UVIR (red housing) UV/IR flame detector
FSL100-UVIR-W (white housing) Suitable for ATEX zone 2/22; FM 3611 Class 1, 2 & 3 Div 2
EN54-10 (HIGH sensitivity) certificate
FM3260 approval (pending*)
FSL100-IR3 (red housing) Triple IR flame detector
FSL100-IR3-W (white housing) Suitable for ATEX zone 2/22; FM 3611 Class 1, 2 & 3 Div 2
EN54-10 (HIGH sensitivity) certificate
FM3260 approval (pending*)
FSL100-SM21 Swivel mount (White)
FSL100-TL FSL100 test lamp, incl. universal charger and carrying case; safe areas only
FSL100-TLX FSL100 test lamp, incl. carrying case; intrinsically safe; hazardous area

-------------------